75
Configuration Mode - Complete menu (FULL)
Code Name/Description Adjustment range Factory setting
FUn-
Function menu (continued)
SPL-
Speed limit menu
LSP
Low speed
0 Hz to HSP 0 Hz
Motor frequency at minimum reference.
This parameter is already included in "my menu" section, page 44
.
tLS
Low speed operating time
0.1 to 999.9 s nO
Following operation at Low speed LSP for a defined period, a motor stop is requested automatically. The
motor restarts if the frequency reference is greater than Low speed LSP and if a run command is still
present.
Important: nO corresponds to an unlimited period.