5 / 52
1.6 CONSIGNMENT CONDITIONS
Gear units are supplied by BONFIGLIOLI RIDUTTORI in the following conditions:
• Congured for installation in the mounting position specied in the purchase order.
• Not charged with lubricant and with internal components protected by a lm of oil compatible
with the recommended lubricant.
• All surfaces and mating parts are treated with rustproong products.
• Mating surfaces are not painted while the unit’s exterior is treated with a coat of grey wa-
ter-based rustproong primer (RAL 7042/C441). Application of a top coat is the responsibility of
the Client.
• Tested to factory standards.
• Packaged suitably for the nal destination.
2.0 TECHNICAL INFORMATION
2.1 DESCRIPTION OF THE GEAR UNIT
The gear unit, driven by an electric or hydraulic motor, has been designed and constructed for
integration into an assembly of interlocking parts or mechanisms as part of a specic application.
Depending on the requirements of the application, the gear unit can be supplied in a variety of
motor executions and congurations. It is capable of satisfying a range of specic requirements in
the mechanical, chemical, agricultural and food industries, etc.
BONFIGLIOLI RIDUTTORI supplies a range of accessories and optionals to make their products
as versatile as possible. For further technical information and descriptions, refer to the corre-
sponding Sales Catalogue.
The User is responsible for using the products recommended for installation and maintenance of
BONFIGLIOLI RIDUTTORI gear units in an appropriate manner and in accordance with instructions.
SAFETY SPECIFICATIONS OF GEAR UNITS COMPLYING WITH DIRECTIVE 2014/34/EU
• unit selection must be made with a higher safety service factor
• use only synthetic lubricants (oil and grease)
• Use only uoroelastomer seals.
• vent plugs with spring-loaded anti-intrusion valve
• oil plugs with aluminium washer
• oil seals with dust trap
• no metal moving parts external to the gear unit
• no plastic parts capable of building up an electrostatic charge, or, if present, duly shielded
• for installations in zones 21 and 22 the User must schedule and implement a regular cleaning
programme for all surfaces and recesses to avoid dust build ups of more than 5 mm in depth.