50
—
Verica termica non necessaria / Thermal verication not necessary / Wärmeprüfung nicht erforderlich
*
HDP 70 n
1
= 1750 min
-1
Tamb = 20°C Tamb = 40°C
i n
2
Mn
2
Pn
1
P
T
P
TFANL / R
P
TSR
P
T
P
TFANL / R
P
TSR
[min
-1
] [Nm] [kW] [kW] [kW] [kW] [kW] [kW] [kW]
HDP 70 2 8.0 218 5100 121 * * * * * *
HDP 70 2 9.3 188 5300 108 * * * * * *
HDP 70 2 10.1 173 5450 103 * 69 81 * * *
HDP 70 2 11.7 149 5650 92 * 69 81 * * *
HDP 70 2 12.6 139 5900 90 54 69 81 36 50 68
HDP 70 2 14.6 120 6100 80 54 69 — 36 50 68
HDP 70 2 15.2 115 6300 79 54 69 — 36 50 68
HDP 70 2 17.7 99 6500 70 54 69 — 36 50 68
HDP 70 2 19.4 90 6550 64 54 — — 36 50 —
HDP 70 2 22.6 78 6850 58 54 — — 36 50 —
HDP 70 3 25.5 69 6500 50 33 47 — * 30 —
HDP 70 3 29.6 59 6850 45 33 — — * 30 —
HDP 70 3 31.7 55 6000 37 33 — — * 30 —
HDP 70 3 36.9 47 6200 33 — — — * 30 —
HDP 70 3 38.5 45 6400 32 — — — 23 30 —
HDP 70 3 44.7 39 6450 28 — — — 23 — —
HDP 70 3 49.1 36 6750 27 — — — 23 — —
HDP 70 3 57.0 31 6850 23 — — — 23 — —
HDP 70 3 63.7 27.5 6050 18.5 — — — — — —
HDP 70 3 73.9 23.7 6650 17.5 — — — — — —
HDP 70 3 77.2 22.7 6600 16.6 — — — — — —
HDP 70 3 89.6 19.5 6850 14.9 — — — — — —
HDP 70 3 98.5 17.8 6750 13.3 — — — — — —
HDP 70 3 114.4 15.3 6850 11.7 — — — — — —