59
—
Verica termica non necessaria / Thermal verication not necessary / Wärmeprüfung nicht erforderlich
*
HDP 90 n
1
= 1400 min
-1
Tamb = 20°C Tamb = 40°C
i n
2
Mn
2
Pn
1
P
T
P
TFANL / R
P
TSR
P
T
P
TFANL / R
P
TSR
[min
-1
] [Nm] [kW] [kW] [kW] [kW] [kW] [kW] [kW]
HDP 90 2 7.9 177 12500 241 102 136 150 * 95 118
HDP 90 2 8.8 159 13100 227 102 136 150 * 95 118
HDP 90 2 10.1 139 13550 206 102 136 150 74 95 118
HDP 90 2 11.2 125 14200 194 102 136 150 74 95 118
HDP 90 2 12.2 115 14350 179 102 136 150 74 95 118
HDP 90 2 13.6 103 15100 169 102 136 150 74 95 118
HDP 90 2 15.8 89 15350 148 102 136 — 74 95 118
HDP 90 2 17.6 80 16400 142 102 — — 74 95 118
HDP 90 2 20.1 70 16450 125 102 — — 74 95 118
HDP 90 2 22.4 63 16750 114 102 — — 74 95 —
HDP 90 3 25.4 55 15600 96 64 87 86 43 60 65
HDP 90 3 28.3 49 16200 89 64 — 86 43 60 65
HDP 90 3 32.9 43 16700 79 64 — — 43 60 65
HDP 90 3 36.6 38 16750 71 64 — — 43 60 65
HDP 90 3 40.0 35 16150 63 — — — 43 60 —
HDP 90 3 44.6 31 16750 59 — — — 43 — —
HDP 90 3 51.8 27.0 17450 52 — — — 43 — —
HDP 90 3 57.7 24.3 16750 45 — — — — — —
HDP 90 3 65.8 21.3 17650 42 — — — — — —
HDP 90 3 73.3 19.1 16750 36 — — — — — —
HDP 90 3 77.8 18.0 17250 35 — — — — — —
HDP 90 3 86.6 16.2 16750 30 — — — — — —
HDP 90 3 98.9 14.2 17650 28 — — — — — —
HDP 90 3 110.1 12.7 16750 24 — — — — — —