EasyManuals Logo

BONFIGLIOLI Vectron Syn10 T400 05 AF User Manual

BONFIGLIOLI Vectron Syn10 T400 05 AF
58 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #8 background imageLoading...
Page #8 background image
4
4
When power is applied
WARNING
z
Do not attempt to install or remove input or out put connectors of inverter when the
power supply is turned on. Otherwise, the inverter may be damaged due to the
surge peak caused by the insertion or removal of power.
z
When momentary power loss is longer than 2 seconds (the large of horse power,
the longer of time), the inverter does not have enough storage power to control the
circuit; Therefore, when power is regenerated, the operation of the inverter is
based on the setup of F_10 and the condition of external switch, this is considered
to be
restart
in the following paragraphs.
z
When the momentary power loss is short, the inverter still has enough storage
power to control the circuit; therefore, when power is regenerated, the inverter will
automatically start operation again depends on the setup of F_23.
When restart the inverter, the operation of the inverter is based on the setup of
F_10 and the condition of external switch (FWD/REV button). Attention: the
restart operation is irrelevant with F_23/F_24.
(1) When F_10=0, the inverter will not start after restart.
(2) When F_10=1 and the external switch (FWD/REV button) is OFF, the inverter
will not start after restart.
(3) When F_10=1 and the external switch (FWD/REV button) is ON, the inverter
will start automatically after restart. Attention: Base on safety reason, please
turn off the external switch (FWD/REV button) after power loss to avoid
possible damage to the machine and the human body after sudden
regeneration of power.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BONFIGLIOLI Vectron Syn10 T400 05 AF and is the answer not in the manual?

BONFIGLIOLI Vectron Syn10 T400 05 AF Specifications

General IconGeneral
CategoryController
ModelVectron Syn10 T400 05 AF
Output current5 A
Frequency50/60 Hz
Power2.2 kW
Protection classIP20
Communication interfaceModbus RTU
Operating temperature0...+40 °C
Input voltage400V AC