DANGER!
Risk of electric shock from damaged power
supply cable
If the power supply cable is damaged (e.g. during
installation or by coming into contact with hot
cooking surfaces), this can cause an (lethal)
electric shock.
XX
Make sure that the power supply cable does not
become trapped or damaged.
XX
Make sure that the power supply cable does not
come into contact with hot cooking surfaces.
Special safety instructions for the installation
of gas cooktops
i
Gas installation, appliance installation and
replacing the gas nozzles, as well as changing
the gas type and pressure, may only be carried
out by reliable trained specialists, who are
familiar with and comply with the standard
national regulations and supplementary
regulations of the local utility companies.
XX
Observe the special instructions on changing the
gas type and pressure and the specifications for
changing the gas nozzles in the nozzle table
(see Operating instructions).
BORA gas cooktops must only be used with BORA
cooktop extractors.
ÿ
DANGER!
Risk of explosion and asphyxiation from gas
Leaking gas can lead to an explosion and result
in severe injuries and property damage, or
asphyxiation.
XX
Keep sources of ignition (naked flames, electric
fires) away and do not operate any light
switches, or switches on electrical appliances.
XX
Do not remove plugs from sockets (risk of
sparking).
XX
Close the gas supply immediately and turn off
the mains supply.
XX
Ensure there is a good supply of fresh air (open
doors and windows).
XX
Plug any leaks immediately.
Special safety instructions for the planning of
extractor systems
ÿ
DANGER!
Risk of smoke inhalation
When the cooktop extractor is used in exhaust
air mode, it draws in air from the room it is
installed in and from neighbouring rooms. If there
is insucient air supply, low pressure will occur.
When used at the same time as a replace that
is dependent on the air in the room, noxious
gases can be sucked into the living areas from the
chimney or outlet shaft.
XX
Make sure that there is always a sufficient air
supply.
XX
Only use reliable, tried-and-tested switching
devices, (e.g. window contact switch, low
pressure warning device) and have them
approved by a qualified expert (certified chimney
sweep).
Ducting connected to wall sleeves
In the case of straight ducting and a distance
< 900mm between the fan and wall sleeve, a
safety guard must be provided for (available as an
accessory).
2.3.2 Safety instructions for cooktop
installation
ÿ
DANGER!
Risk of electric shock from incorrect mains
connection
Connecting the appliance to the mains incorrectly
poses a risk of electric shock.
XX
Make sure that the appliance has a fixed
connection to the mains voltage.
XX
Make sure that the appliance is connected to a
properly installed protective conductor system.
XX
Make sure that technical equipment is provided
to enable all of the appliance’s poles to be
disconnected from the mains with a contact
opening width of at least 3 mm (LS switch and
automatic circuit breakers, fuses, contactor).