30/68 Transport and storage
Bosch Rexroth AG, A4VG Series 32, RE 92003-01-B/12.2015
6.2 Storing the axial piston unit
The storage areas must be free of corrosive materials and gases.
To prevent damage to the seals, ozone-forming equipment (e.g., mercury-vapor
lamps, high voltage equipment, electric motors, sources of electrical sparks or
electrical discharge) must not be operated in storage areas.
The storage areas must be dry.
Recommended relative humidity ≤60%.
Ideal storage temperature: +5 °C to +20 °C.
Minimum storage temperature: −50 °C.
Maximum storage temperature: +60 °C.
Keep out of direct sunlight.
Do not stack axial piston units and store them in a shock-proof manner.
Do not store the axial piston unit on the drive shaft or attachments, e.g., sensors
or valves.
For further storage conditions, see Table 7.
Check the axial piston unit monthly to ensure proper storage.
The axial piston units are provided ex-works with anti-corrosion packaging (corrosion
protection film).
Table 7 lists the maximum permissible storage times for an originally packed axial
piston unit as per data sheet 90312.
Table 7: Storage time with factory corrosion protection
Storage conditions Standard corrosion protection Long-term corrosion
protection (optional)
Closed, dry room, at a uniform
temperature between +5°C
and +20°C and an undamaged
and sealed corrosion
protection film.
Maximum 12 months Maximum 24 months
Warranty is void if the requirements and storage conditions are not observed or
after expiration of the maximum storage time (see Table 7).
Procedure after expiration of the maximum storage time:
1. Check the entire axial piston unit for damage and corrosion prior to installation.
2. Perform a test run to check the axial piston unit for proper function and
leak-tightness.
3. If the storage time exceeds 24months, the shaft seal must be replaced.
After expiration of the maximum storage time, we recommend that you have the
axial piston unit inspected by your BoschRexrothService partner.
In the event of questions regarding repair and spare parts, contact your responsible
BoschRexrothService partner or the service department of the manufacturer's plant
for the axial piston unit, see Chapter10.5 “Spare parts” on page56.
Requirements
After delivery

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch A4VG A4VG 32 Series and is the answer not in the manual?

Bosch A4VG A4VG 32 Series Specifications

General IconGeneral
BrandBosch
ModelA4VG A4VG 32 Series
CategoryWater Pump
LanguageEnglish

Related product manuals