EasyManua.ls Logo

Bosch AMAX 4000 - How to isolate;unisolate a zone via LED;LCD keypad; How to view isolated zones

Bosch AMAX 4000
38 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Data
Panel AMAX2100 AMAX3000 AMAX4000
Enclosure:
Dimensions
(HxWxD):
260 x 280 x 83.5mm (L x W x H) 375 x 322 x 88 mm(L x W x
H)
Weight: 1950g 4700g
Environmental Considerations:
Relative Humidity: 10% - 95%
Operating
Temperature:
-10°C - +55°C
Ingress protection
rating:
IP 30
Security level: IK 06
Supervised Zones:
Onboard:
Z1: Single or dual end-of-line (EOL 2,2KΩ)
NC, NO
2 wire fire zone, Single, or
dual end-of-line (EOL
2,2KΩ)
NC, NO
Z2 - Z16 COM: 7 Single or dual end-of-line (EOL 2,2KΩ)
NC, NO
15 Single or dual end-of-line
(EOL 2,2KΩ)
NC, NO
Tamper: Enclosure tamper input (does not reduce point capacity)
Outputs (PO):
Programmable Onboard:
PO -1 / PO -2: supervised output a maximum of 500mA
PO -3: max 100mA
PO +3 / PO +4: +12V / max 750mA
Watchdog PO -5: max 100mA
Number of...
Zones: 8 16 32
Users: 64 128 250
Key Fob Users: DSRF = 24, Radion = 128
Events: 256 history events, stamped with time, and date
256EN history events, stamped with time, and date
256 dialer history events, stamped with time, and date
6
AMAX 2100 / 3000 / 4000 Technical Data | en 31
Bosch Sicherheitsysteme GmbH Quick Start Manual 2014.11 | 02 | F.01U.309.297

Other manuals for Bosch AMAX 4000