6. Enter 00 for the zone function 00-not used and press [#].
The system displays the next menu item: ZONE IN AREA. There is no need to proceed to
the following menu items for deleting a zone.
7. Press [–] four times to get to the EXIT PROG. +SAVE menu.
8. Press [#] to save the data end exit the programming mode.
P The selected zone is deleted (example: zone 1 is deleted).
Enabling the RF Receiver for Wireless Communication
1. Enter the installer code [1234] + [958] and press [#].
2. Select 7 RF MANAGER and press [#].
3. Select RF SETTING and press [#].
4. Select RF RECEIVER and press [#].
5. Select 1-enable and press [#].
6. Press [#] to confirm.
7. Press [–] three times to get to the EXIT PROG. +SAVE menu.
8. Press [#] to save the data end exit the programming mode.
P The RF receiver for wireless communication is enabled.
Setting up a Zone for an RF Device
1. Enter the installer code [1234] + [958] and press [#].
2. Select 3 ZONE MANAGER and press [#].
3. Select ADD/DELETE ZONES and press [#].
The system displays the next menu item: INPUT ZONE No.
4. Enter the number of the zone to which you to assign the RF device and press [#].
The system displays the next menu item: ZONE MODULE SEL.
5. Select the correct zone module depending on the RF device:
For RFUN / RF3401E (Zone input only) select 5-RF RFUN no magn
For RFGB / RF1100E (Glass Break Detector) select 4-RF RFGB glassb.
For all other RF devices (Zone input only) select 3-RF all
6. Press [#] to confirm.
The system displays the next menu item: ZONE FUNCTION.
7. Enter 01 for the zone function 01-instant and press [#].
The system displays the next menu item: ZONE IN AREA.
8. Enter the number of the area you want to assign to this zone and press [#].
The system displays the next menu item: ZONE RFID: MANUAL.
9. Enter the RF ID manually (9 digits).
Or
Press and hold [*] for three seconds to switch to the ZONE RFID: AUTO menu.
Trigger the RF device to give alarm once.
The RF ID will be entered automatically.
10. Press [#] to confirm.
The system displays ZONE NAME INPUT [a]
11. Enter a zone name and press [#] to confirm.
The system displays again: INPUT ZONE No.
12. Press [–] four times to get to the EXIT PROG. +SAVE menu.
13. Press [#] to save the data end exit the programming mode.
P The selected zone is set up for an RF device.
5.4.4
5.4.5
22 en | Programming and operating the AMAX panel AMAX panel
2016.05 | 06 | F.01U.309.297 Quick Installation Guide Bosch Sicherheitssysteme GmbH