Technical data
Electrical
AMAX 2100 AMAX 3000 AMAX 3000
BE
AMAX 4000
Power supply type EN = A
Panel PCB maximum quiescent
current in mA
100
Transformer
Transformer input in VAC 230
Transformer output in VAC 18
Transformer AC power in VA 20 50
Transformer fuse in mA 500 1000
AC input
Minimum operating voltage in
VDC
195
Maximum operating voltage in
VDC
253
Line voltage frequency in Hz 50
DC output
DC output maximum current for
all components in mA
1100 2000
DC output maximum current for
all components: dependency on
battery
– Battery 7Ah standby 12h (recharge Batt 80% in 72h) =
550mA
– Battery 7Ah standby 36h + 15min alarm current
500mA (recharge Batt 80% in 72h) = 150mA
– Battery 18 Ah standby
12h (recharge Batt 80%
in 72h) = 1500mA
– Battery 18Ah standby
36h (recharge Batt 80%
in 24h) = 480mA
– Battery 18Ah standby
36h + 15min alarm
current 1000mA
(recharge Batt 80% in
24h) = 400mA
Aux 1 / 2 output
Aux 1 / 2 output voltage +12V / GND
Aux 1 / 2 nominal output voltage
under AC line input in VDC
13.8 (+3% / -5%)
6
24 en | Technical data AMAX panel
2016.05 | 06 | F.01U.309.297 Quick Installation Guide Bosch Sicherheitssysteme GmbH