20 Instant Report
21 Reserved
Force Arm / Bypass 0 Disabled
1 Force Arm
2 Bypass
3 All
Silent Alarm / Chime
Mode
0 Disabled
1 Silent Alarm
2 Chime Mode
3 All
Zone Pulse count 0 Disabled
1-9 1-9 Pulses
Zone Lockout 0 Disabled
1 1 Times Alarm Lockout
2 3 Times Alarm Lockout
3 6 Times Alarm Lockout
4 Alarm Duration
Zone Tamper (DEOL) 0 Disabled
1 Enabled
Zone Status Report 0 No Report Required
1 Receiver 1
2 Receiver 2
3 Receiver 3
4 Receiver 4
5 Receiver 1, 2, 3 and 4
6 Receiver 1 (2, 3 and 4 for backup)
7 Receiver 1 (2 for backup) and Receiver 3 (4 for backup)
Unverified Alarm
Report / Cross Zone
0 Disabled
1 Unverified Alarm Report
2 Cross Zone
3 All
Domestic Call Follow 'Alarm report' Option's Logic. Range 0-7
0 No Reports Allowed
1 Report to Destination 1
AMAX panel 4000 / AMAX panel 4000
EN
Programming | en 119
Bosch Sicherheitsysteme GmbH Installation Guide 2013.07 | 03 | F.01U.267.112