B 426 or DX 4020 or DX
4020G (only 1):
2
DX2010: 6
DX 4010: 1
RF Receiver: 1
RF Repeater: DSRF = 0, Radion = 8
RF Sensors: 64
RF Keyfobs: DSRF = 24, Radion = 128
Power:
Power Supply Type: EN = A
Transformer: 230V Input/18VAC 50VA Fuse=1A
AC Input: AC Input Voltage: 195 VAC to 253 VAC
Line Voltage Frequency: 50 Hz
DC Output: maximum current for all components 2000mA
max current for all components Battery 7Ah standby
12h (recharge Batt 80% in 72h) = 550mA
max current for all components Battery 17Ah standby
12h (recharge Batt 80% in 72h) = 1500mA
max current for all components Battery 17Ah standby
36h (recharge Batt 80% in 24h) = 480mA
Aux 1(+12V/GND) Output: Nominal Output Voltage under AC line input: 13,8 VDC
+3% / -5%
Output Voltage Range under AC line input: 13.11 VDC
to 14.2 VDC
900mA maximum
Vpp (max) 675mV
Aux 1(+12V/GND) Output: Nominal Output Voltage under AC line input: 13,8 VDC
+3% / -5%
Output Voltage Range under AC line input: 13.11 VDC
to 14.2 VDC
900mA maximum
Vpp (max) 675mV
Option Bus 1: Nominal Output Voltage under AC line input: 13,8 VDC
+3% / -5%
Output Voltage Range under AC line input: 13.11 VDC
to 14.2 VDC
900mA maximum
Option Bus 2: Nominal Output Voltage under AC line input: 13,8 VDC
+3% / -5%
Output Voltage Range under AC line input: 13.11 VDC
to 14.2 VDC
900mA maximum
172 en | Technical Data
AMAX panel 4000 / AMAX panel 4000
EN
2013.07 | 03 | F.01U.267.112 Installation Guide Bosch Sicherheitsysteme GmbH