EasyManua.ls Logo

Bosch AUTODOME 7000 VG5-7230 - 14.19 VCA Configuration; VCA Setup and Motion Detection

Bosch AUTODOME 7000 VG5-7230
152 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SSL encryption
The data for the connection, for example the password, can be securely transmitted with SSL
encryption. If you have selected the On option, only encrypted ports are offered in the Remote
port parameter.
Notice!
Please note that the SSL encryption must be activated and configured at both ends of a
connection. This requires the appropriate certificates to be uploaded onto the camera.
You can activate and configure encryption of the media data (video and metadata) on the
Encryption page (see Encryption, page 128).
Auto-connect
Select the On option to automatically re-establish a connection to one of the previously
specified IP addresses after each reboot, after a connection breakdown or after a network
failure.
Notice!
In the default setting, Stream 2 is transmitted for automatic connections. Bear this fact in
mind when assigning the profile (see Encoder Profile, page 96).
Audio
Select On to activate audio alarms.
VCA
The camera has integrated video content analysis (VCA), which can detect and analyze
changes in the signal on the basis of image processing. Such changes can be due to
movements in the camera's field of view.
You can select various VCA configurations and adapt these to your application as required. The
Silent MOTION+ Configuration is active by default. In this configuration, metadata is created
to facilitate searches of recordings; however, no alarm is triggered.
1. Select a VCA configuration and make the required settings.
2. If necessary, click the Default button to return all settings to their default values.
Intelligent DNR (Digital Noise Reduction)
IVA / VCA controls the iDNR feature, which reduces noise based on motion activity in the
scene. When there is no motion in the preset scene, noise reduction is increased. When there
is motion detected in the preset scene, noise reduction is decreased to reduce bandwidth and
optimize storage space.
To disable the iDNR feature, select the OFF option in the VCA configuration field.
To enable iDNR, select a Profile # (1 – 16) or Silent VCA in the VCA configuration field. If you
select a specific profile, you must also select MOTION+ in the Analysis Type field.
VCA Profiles
You can configure two profiles with different VCA configurations. You can save profiles on your
computer's hard drive and load saved profiles from there. This can be useful if you want to
test a number of different configurations. Save a functioning configuration and test new
settings. You can use the saved configuration to restore the original settings at any time.
14.32
114 en | Configuration via IP, Advanced Mode AUTODOME 7000
2014.04 | 2.0 | F.01U.283.679 Operation Manual Bosch Security Systems, Inc.