Next, specify up to two (2) rule outputs, or the camera’s response to the input. Outputs
include a physical alarm relay, an AUX command, or a preposition scene.
1. Click the Enabled check box to activate the alarm.
2. Choose one of the following alarm Inputs:
Local Input 1: a physical alarm connection.
Local Input 2: a physical alarm connection.
IVA/MOTION+: an alarm when IVA or motion detection is activated.
Connection: an alarm when an attempt is made to access the camera’s IP address.
3. Choose one of the following output commands for both Output 1 and Output 2 settings:
None: no defined command.
Alarm Relay: defines a physical connection from the open collector alarm output.
Aux On: defines a standard or custom keyboard ON command. Refer to User Command
Table, page 149 for a list of valid commands.
Note: Only commands 1, 8, 18, 20, 43, 60, 80, 86 are supported. Support for the
remaining commands is scheduled for a future release.
Aux Off: defines a standard or custom keyboard OFF command. Refer to to User
Command Table, page 149 for a list of valid commands.
Note: Only commands 1, 8, 18, 20, 43, 60, 80, 86 are supported. Support for the
remaining commands is scheduled for a future release.
Shot: defines a preset scene from shot 1-256.
4. Click Set to save and to activate the alarm rules.
Advanced Mode: Interfaces
Alarm Inputs
Select the type of input for each physical alarm. Select from either N.O. (Normally Open) or
N.C. (Normally Closed) and provide an optional name for each input.
Alarm Outputs
The camera incorporates three (3) open collector alarm or transistor outputs. Use the
following settings to configure the relay for alarm outputs.
Idle state
Specify either Open or Closed idle state.
Operating mode
Select one of the following modes for operation: Bistable, 0.5 s, 1 s, 5 s, 10 s, or 60 s.
Output name
Type an optional name for the relay connection, up to 20 characters.
Trigger output
Click the appropriate Trigger output button to test the relay / output connection.
14.38
14.39
14.40
AUTODOME 7000 Configuration via IP, Advanced Mode | en 121
Bosch Security Systems, Inc. Operation Manual 2014.04 | 2.0 | F.01U.283.679