Connecting Alarm Inputs and Outputs
4 To connect alarm inputs and outputs, attach the supplied 6-pin Alarms In and the 4-pin
Alarms Out connector plugs with flying lead wires to the appropriate incoming alarm
wires. Alarm Out 4 is a relay.
Figure 8.1: Alarm and relay connectors
1
4-pin Alarm
Connector (P102)
2 6-pin Alarm In
Connector (P103)
3 7-pin Relay Connector (P104)
Pin Description Pin Description Pin Description
1 Alarm Out 1 1 Alarm in 3 1 Alarm Out 4 Normally Open
2 Alarm Out 2 2 Alarm in 4 2 Alarm Out 4 COM
3 Alarm Out 3 3 Alarm in 5 3 Alarm Out 4 Normally Closed
4 Alarm Ground 4 Alarm in 6 4 Earth Ground
5 Alarm in 7 5 Analog Alarm 1
6 Alarm Ground 6 Analog Alarm 2
7 Ground
For in-ceiling mount only: Low Voltage TTL (3.3V) can also be used.
4 If you are connecting supervised alarms and relays, attach the supplied 7-pin Relay
Connector to the appropriate incoming wires. Refer to Make Connections in the Power
Supply Box, page 33 for additional information.
Power Supply Box Connections
The following figure is a detailed illustration of the Pendant Arm Power Supply Box, which
includes the fuse specifications.
26
en | Installing the Pendant Arm Wall, Corner, and Mast (Pole) Mounts AUTODOME 7000
2014.04 | 2.0 | F.01U.283.679 Operation Manual Bosch Security Systems, Inc.