EasyManua.ls Logo

Bosch B5512 - Send System Status Report

Bosch B5512
160 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Panel event Modem4 code
D6500 mode
Modem4 code
Bosch SIA mode
Contact ID event Contact ID code
Armed PartOn instant Csiii Nriaa/idiiiiNL Armed STAY 3 441 aa uuu
Aux Overload Tsss9 NYM Low System Battery 1 302 00 000
Aux Overload Restore Rsss9 NYR Low System Battery
Restore
3 302 00 000
Battery Charger Circuit
Trouble
Tsss9 NYT System Trouble 1 300 00 000
Battery Charger Circuit
Trouble Restoral
Rsss9 NYR System Trouble Restore 3 300 00 000
Bypass by Sked Nspppp Nriaa/
aikkkUBpppp
Zone/Sensor Bypass 1 570 aa ppp
Bypass by User Nspppp Nriaa/
idiiiiUBpppp
Zone/Sensor Bypass 1 570 aa ppp
Cellular Fewer than Two
Towers
TssssD NpiddddET System Peripheral Trouble 1 330 00 zzz
Cellular Fewer than Two
Towers Restoral
RssssD NpiddddER System Peripheral Trouble
Restore
3 330 00 zzz
Cellular Low Signal TssssD NpiddddET System Peripheral Trouble 1 330 00 zzz
Cellular Low Signal Restoral RssssD NpiddddER System Peripheral Trouble
Restore
3 330 00 zzz
Cellular No Tower Available TssssD NpiddddET System Peripheral Trouble 1 330 00 zzz
Cellular No Tower Available
Restoral
RssssD NpiddddER System Peripheral Trouble
Restore
3 330 00 zzz
Cellular Service Not Activated TssssD NpiddddET System Peripheral Trouble 1 330 00 zzz
Cellular Service Not Activated
Restoral
RssssD NpiddddER System Peripheral Trouble
Restore
3 330 00 zzz
Change another’s password
or card
NsDO4 NidiiiiiJViiiii Local Only Local Only
Change own password NsDO4 NidiiiiiJViiiii Local Only Local Only
Checksum failure on
configuration memory
TsD15 NYF RAM Checksum Bad 1 303 00 000
Closing by Account Csiiii NidiiiiCL O/C by account 3 401 00 uuu
Closing by Area Csiiii Nriaa/idiiiiCL O/C by User 3 401 aa uuu
Closing Early by Area Csiiii Nriaa/idiiiiCK Early O/C 3 451 aa uuu
Closing Late by Area Csiiii Nriaa/idiiiiCJ Late O/C 3 452 aa uuu
Communication failure by
route group
TsB01 NrggYC Failure to communicate
event
1 354 00 000
Control Panel Reporting and device number information | en 149
Bosch Security Systems, Inc. Installation and System Reference Guide 2015.07 | 12 | F.01U.287.180

Table of Contents

Other manuals for Bosch B5512

Related product manuals