Reporting and device number information
This section contains information to help you understand control panel reports.
Report format definitions
Notice!
Control panels using Modem4 send 4-digit Point and User data.
Panel event Modem4 code
D6500 mode
Modem4 code
Bosch SIA mode
Contact ID event Contact ID code
A point supervisory condition
occurred
Jspppp NriaBSpppp 24 hour Non-Burglary 1 150 aa ppp
A valid local RPS access
occurred
RsF01 NLS Successful Download/
Access
1 412 00 000
A valid remote RPS access
callback occurred
RsssF NphhhRS Successful Download/
Access
1 412 00 000
A valid remote RPS access
occurred
RsssF NRS Successful Download/
Access
1 412 00 000
AC Fail – mains power supply Pssss NAT AC Loss 1 301 00 000
AC Restore – mains power
supply
Rsss0 NAR AC failure restore 3 301 00 000
Add Key Fob to a User
(Assign Card Event)
NsD30 NidiiiiDAiiii Local Only Local Only
Alarm Aspppp NriaBApppp Burglary 1 130 aa ppp
Alarm Cross Point Aspppp NriaBMpppp Burglary 1 130 aa ppp
Alarm Exit Error Aspppp Nria/idiiiiEApppp Entry/Exit 1 134 aa ppp
Alarm with Recent Closing Aspppp Nria/CRpppp Entry/Exit 1 459 aa uuu
All Points Tested by User RsssF NRilTC Local Only Local Only
All SDI devices are missing,
power is shorted
TsssD NpiET Expansion Module Failure 1 333 00 000
All SDI devices are restored,
power is normal
RsssD NpiER Expansion Module Failure
Restore
3 333 00 000
An invalid RPS remote access
callback occurred
TsssF Np004RU Unsuccessful Access 1 413 00 000
An invalid RPS remote access
occurred
TsssF NRU Unsuccessful Access 1 413 00 000
Area Watch End NsD52 Nriaa/idiiiiTZ Local Only Local Only
Area Watch Start NsD51 Nriaa/idiiiiTW Local Only Local Only
Armed PartOn delay Csiiii Nriaa/idiiiiNL Armed STAY 3 441 aa uuu
21
21.1
148 en | Reporting and device number information Control Panel
2015.07 | 12 | F.01U.287.180 Installation and System Reference Guide Bosch Security Systems, Inc.