Open collector outputs
OUTPUT B and C
B C
OUTPUT
Outputs B and C are open collector outputs that can sink up to 50 mA of power (+12 VDC),
when activated.
As an example, the figure below shows using Outputs B and C to trigger the relays of a D134
Dual Relay Module.
N/O 1
COMM 1
N/C 1
X1 +
X1 -
COMM 2
N/O 2
N/C 2
X2 +
X2 -
2
1
3.7 - 5.0 VDC
2.0 - 3.0 VDC
0.0 - 1. 3 VDC
Open
Normal
Short
C
OUTPUT
B
USB
ETHERNET
100BASE-T
LINK
COMMUNICATION MODULE 1
1 k End of Line Resistors
Voltage Ranges
ON-BOARD POINTS
3 COM 4 5 COM 61 COM 2
R Y G B
SDI2
Device Bus
18 VAC
BATTERY OUTPUT A
AUX
- 12 V +
OUTPUT A
OUTPUT A
Jumper Under Cover
AUX PWR
COM
DRY
TMPR
1 COM 2 7 COM 83 COM 4 5 COM 6
RESET
ETHERNET
COM AUX
R Y G B
PWR A B COM
+ BAT -
18VAC
B C
OUTPUT
NO C NC
OUTPUT A
7 COM 8
Figure 10.1: OUTPUT B and C wiring (B5512 shown)
Callout á…³ Description
1 á…³ Control panel
2 á…³ D134 Dual Relay Module
Use OUTPUT PARAMETERS in RPS to configure programmable outputs.