Flash pattern Function
RX (Receive) Flashing
Occurs when the module receives a message over the
network connection – UPD, TCP, or DNS.
TX (Transmit) Flashing
Occurs when the module sends a message over the
network connection – UPD, TCP, or DNS.
Table 8.6: RX and TX LEDs descriptions
LINK (yellow) LED pattern
100Mb (green) LED pattern Function
Off Off
No Ethernet link
On Steady
Off
10Base-T link
Flashing
Off
10Base-T activity
On Steady On Steady
100Base-TX link
Flashing
On Steady
100Base-TX activity
Table 8.7: Ethernet Link LEDs descriptions
B450 Conettix Plug-in Communicator Interface
The B450 Conettix Plug-in Communicator Interface gives the ability to connect more than one
cellular plug-in communicator to the control panel by providing an interface to the control
panel’s SDI2 wiring.
The B450 supports one cellular plug-in module.
B450 Conettix Plug-in Communicator Interface connects to the SDI2 bus on the control panel
using terminals PWR, A, B, and COM, or using the SDI2 interconnect wiring connector. This
section includes basic installation instructions. For detailed installation instructions, refer to
the Conettix Plug-in Communicator Interface (B450) Installation and Operation Guide.
8.4
Control Panel IP communications | en 47
Bosch Security Systems, Inc. Installation and System Reference Guide 2015.07 | 12 | F.01U.287.180