Error Memory | 7
Bosch Motorsport Data Logger C 70 Manual 39/112
7.2 Information on errors available from the
error memory
In general, properties of the error memory and properties of an individual error need to
be distinguished.
7.2.1 Error Memory Properties
The following property is available for the error memory itself:
Error Status (device measurement label “error_state”)
0: no error present in memory
1: at least one inactive error present in memory, no active errors
2: at least one active error present in memory
If displayed in a measurement sheet, this property’s value (0, 1 or 2) is translated into a
verbal description: