EasyManua.ls Logo

Bosch C 70 - Power Supply

Bosch C 70
112 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Power Supply | 4
Bosch Motorsport Data Logger C 70 Manual 7/112
4 Power Supply
Please ensure that you have a good ground installation. That means:
A ground that has a solid, low resistance connection to the negative battery terminal
Connection should be free from dirt, grease, paint, anodizing, etc.
Use large diameter wire
More metal-to-metal contact is better!
The following notations for power signals are used:
KL 15 is a switched battery rail controlled by the IGN-switch
KL 30 is an unswitched battery positive rail (same as battery positive terminal)
KL 31 is an unswitched ground rail (same as battery negative terminal)
Be careful to observe current limits of wires and connector pins!

Related product manuals