Fig. 33 Setting operating times
[1] Start of the first operating time
[2] End of the first operating time
[3] Start of the second operating time
[4] End of the second operating time
Deleting the operating time
Set the start and end of the operating time to the same time.
The operating time is deleted.
If you do not wish to set a second operating time:
Set the start and end of the second operating time to the
same time.
The display will show "--:--".
Fig. 34
" " symbol is displayed
During appliance operating time.
" " symbol is displayed
Outside of appliance operating time.
8.6.3 "Leg" - Automatic thermal disinfection
The "Leg" function allows you to activate/deactivate thermal
disinfection. This process is used to kill bacteria and must be
performed by the user at least once a week.
Fig. 35 "Leg" function
Activating the automatic "Leg" function
Call up the "Leg" function and press "OK".
" " flashes on the display.
▶Press "+".
" " flashes on the display.
▶Press "OK".
The "Leg" function is activated and the first day of the week
flashes.
Set the day of the week for disinfection.
Select the day using the "+" and "-" buttons.
▶Press "OK".
6720646160-38.1V
1 2 3 4
6720804054-14.1V
This function is deactivated on the appliance
at the factory.
When the disinfection is activated, all other
settings are temporarily suspended.
WARNING: Risk of scalding!
Hot water can lead to severe scalding.
Only schedule thermal disinfection for
periods outside normal usage times.
Inform occupants of the building of the
danger of scalding and always monitor
the thermal disinfection process. Install a
thermostatic DHW mixer.
The disinfection takes max. 48 h. During the
first 24 hours, the appliance is in the "Combi"
operating mode. If it does not reach 70 °C,
the appliance switches to the "Full" operating
mode for the next 24 hours.
The DHW temperature is automatically set to
70 °C.