6 720 809 134 (2013/09)Compress 3000 DW FII
About the appliance | 9
3.10 Technical properties
Unit HP270-2E0... HP270-2E1...
Heating output - in accordance with EN255-3, air temperature 20 °C, heating water from 15 °C to 45 °C
Output kW 1,7
Total heating output (including electric booster heater) kW 3,7
Performance coefficient (COP) – 4,3
Heat-up time h 5:00
Heat loss in 24h kWh/day 0,74
Heating output - in accordance with EN16147, XL cycle, air temperature 15 °C, heating water from 10 °C to 54 °C,
Tref > 52.5 °C
Performance coefficient (COP) – 3,20
Heat-up time h 8:48
Heat loss in 24h kWh/day 1,08
DHW volume, corresponds to water at a temperature of 40 °C, available after
heating
l
372
Heating output - in accordance with EN16147, XL cycle, air temperature 7 °C, heating water from 10 °C to 54 °C,
Tref > 52.5 °C
Performance coefficient (COP) – 2,79
Heat-up time h 10:38
Heat loss 24h kWh/day 0,97
Air inlet
Air flow rate (without/with pipework) - fan speed "SP1" m
3
/h 380/300
Air flow rate (without/with pipework) - fan speed "SP2" m
3
/h 490/300
Operating temperature °C -10 ... +35
Refrigerant circuit
Refrigerant R134a g 400
Maximum pressure bar 27
DHW
Cylinder capacity l 270 260
Area of heat exchanger (internal indirect coil) m
2
-1.3
Maximum outlet temperature without/with electric booster heater °C 60/70
DHW volume per day, corresponds to a water temperature of 40 °C, air
temperature 20 °C, heating water from 15 °C to 60 °C
l
1200
Maximum operating pressure bar/MPa 10/1
Electrical details
Mains power supply V ~230 (+10%/-10%)
Frequency Hz 50
Current rating (without/with electric booster heater) O 2.6/11.3
Max. rated consumption kW 0.6
Total heating output of the electric booster heater kW 2.0
Total max. rated consumption (including electric booster heater) kW 2.6
IP rating I
IP rating (without/with pipework) IP 21/24
General data
Table 3