Settings
25
Compress Hybrid 7000i AW – 6721833053 (2020/09)
Table 5 Symbols in the display
8.2 Faults
You can find an overview of the faults that can appear on the display on
our Internet page, which can be found at the address on the back of these
instructions.
8.3 General commissioning of the user interface
Once the user interface is connected to the power supply, the Language
menu appears on the display.
▶ Make adjustments by turning and pressing the selector.
▶ Setting language.
The display changes to the Date menu.
▶ Set the date and confirm with Continue.
The display changes to the Time menu.
▶ Set the time and confirm with Continue.
The display changes to the Country information menu.
▶ Set the country and confirm.
The display changes to the Buffer cylinder menu.
▶ Select Yes, if a buffer cylinder is installed, and confirm.
Otherwise select No and confirm.
The display changes to the Configuration wizard menu.
▶ Start the configuration wizard with Yes (or skip with No).
▶ Commission the system.
8.4 System commissioning with the configuration wizard
The configuration wizard automatically recognises which BUS nodes are
installed in the system. The configuration wizard adjusts the menu and
the factory defaults.
The system analysis may take up to one minute.
After the configuration wizard has performed the system analysis,
the
Commissioning
menu is opened. The sub-menus and settings must
always be checked here and, if necessary, adjusted and finally confirmed.
If the system analysis is skipped, the
Commissioning
menu is opened.
The sub-menus and settings listed here must be carefully adjusted
according to the installed system. Finally, the settings must be confirmed.
For further information on the settings refer to Chapter
8.5
from page
26
.
Item Symbol Explanation
1 Value display (current temperature):
• Room temperature if a remote control is
installed for the actual heating circuit
• Heat source temperature for installation in
heat source.
2 – Info line: display of time of day, day of the
week and date.
3 Additional temperature display: outside
temperature, temperature of the solar
collector or a DHW system.
4 – Text information: e.g. the designation of the
temperature currently displayed ( Fig. 36,
[1]). If a fault is present, corresponding
information will be displayed here until the
fault has been rectified.
5 The key block is active (hold down the DHW
key and selector to activate or deactivate the
key block).
6 Infographic: solar pump is in operation.
Infographic: DHW heating is active
Infographic: DHW thermal disinfection active
Infographic: Extra DHW active
Infographic: Pool heating active
Infographic: Heating active
Infographic: Cooling active
Infographic: Energy supplier interruption
Infographic: External input active (remote)
Infographic: Holiday mode active
Infographic: Time program active
Infographic: Smart grid function active
Infographic: Screed drying active
Infographic: Electric booster heater active
Infographic: Power guard active
Infographic: Additional heat source active
Infographic: Defrost function active
Infographic: Compressor (Heat pump) active
7 Operating
mode
Operating mode: Optimised operation no time
program active.
Operating mode: Program 1 | Program 2
automatic mode active (according to time
program) for displayed heating circuit.
Operating mode: heating mode active.
Operating mode: setback mode active.
Menu item Control range: Function description
Country information
Set the country and confirm.
Buffer cylinder
Select Yes if a buffer cylinder is installed. Otherwise
select No and confirm.
Start configuration wizard
Yes | No: Please ensure before starting the
configuration wizard:
• that the modules are installed and addressed,
• that a remote control is installed and has been
adjusted and
• that an outdoor temperature sensor is installed.
Heat source (not
available for AW
heat pumps)
Borehole: The energy is exchanged through a ground
probe.
Earth: The energy is exchanged through a surface
collector in the soil.
Groundwater: The energy is exchanged by a
groundwater collector.
Extr. air: The energy is recovered by extracting air
from the house and after the exchange releasing it to
the exterior.