Product description
5
Compress Hybrid 7000i AW – 6721833053 (2020/09)
2.4 Possible combinations of indoor and outdoor units
The indoor unit is intended for installation inside the building and for
connection to heat pump outdoor units installed in the open air.
The indoor unit can be used with the following outdoor units:
• CS7001iAW 5 OR
• CS7001iAW 7 OR
• CS7001iAW 9 OR
• CS7400iAW 5
• CS7400iAW 7
2.5 Possible combinations of indoor unit and external
booster heater
The indoor unit can be operated in combination with a gas condensing
appliance, providing the gas condensing appliance satisfies the
following minimum requirements:
• Minimum modulation: factor 4
• Maximum output: 32 kW “(heating) output"
• Integrated heating pump
If the indoor unit is to be operated without a gas condensing appliance,
additional safety equipment must be installed in the heating system in
compliance with the applicable standards and guidelines.
DHW is only provided via the external booster heater (combi boiler)
(Fig. 21)
2.6 Dimensions and Minimum Clearances
Mount the indoor unit high enough so that the control unit is easy to use.
In addition, take pipes and connections under the indoor unit into
account.
Fig. 4 Minimum distance (mm)
Fig. 5 Clearances between connections (mm)
0010028013-003
≥50 ≥50
≥550
≥800
655
757
0010029918-003
350
90 129
100627066
243
62 114
9844
67