Settings in the service menu
33
Condens 8300i W – 6721841531 (2022/10)
Menu 4: Settings
Press the ( key and * key simultaneously until the display shows
L.1.
Press the key repeatedly until L.4 appears.
To confirm the selection: press OK key.
Selecting and setting the service function.
The factory settings are depicted as highlighted in the following table.
Service function Settings/adjustment range Remark/restriction
4-A1 Venting function 0
1: Switched on once (At the end of ventilation,
the setting reverts to the “0” status.)
2: Switched on permanently
The venting function can be switched on after
maintenance work.
During ventilation, the symbol and flow
temperature appear alternately in the display.
4-A2 Siphon filling program 0: (only permissible during maintenance)
1: switched on with minimum appliance
output
2: Switched on with minimum heating
capacity
The siphon filling program is activated
automatically in the following cases:
Once the device is switched on using the On/
Off switch
Once the burner was not in operation for at
least 28 days
Once the operating mode is switched from
summer to winter mode
Once the factory settings of the device have
been restored
The next time there is a heat requirement for
heating, the device is held at low thermal output
for 15 minutes. The siphon filling program
remains active until the device was in operation
with low heat output for 15 minutes.
The symbol and flow temperature appear
alternately in the display for the duration of the
siphon filling program.
4-A3 3-way valve centre position OFF
•ON
To fill the heating system
4-A4 Type of maintenance Setting the service display
0
1: By burner runtime
2: By date (with heating controller)
3: acc. to hours run
4-A5 Burner runtime 10 ... 60 (= 1000 ... 6000 h) This service function is only available if service
function 4-A4 is set to 1 Burner runtime.
After this interval has expired, the display
indicates that an inspection is due via the service
display 1018.
4-A6 Hours run 12 … 72 months This service function is only available if service
function 4-A4 is set to 3 (Operating hours).
After this interval has expired, the display
indicates that an inspection is due via the service
display 1018.
4-b1 Device-internal weather-compensated
control
OFF
•ON
This service function is only available if an outside
temperature sensor is detected in the system.
This service function is no longer available when a
weather-compensated control unit with EMS
connection is connected.
4-b2 Outside temperature limit for automatic
changeover between summer and winter
mode.
0 ... 16 ... 30 °C This service function is only available if service
function 4-b1 is activated.
If the outside temperature exceeds the set
temperature limit, the heating is switched off
(summer mode). If the outside temperature falls
to at least 1 K ( °C) below the setting, the heating
is switched back on (winter mode).

Table of Contents