Menu structure
Control 8310 – 6720856493 (2022/07)
12
10 Menu structure
The control unit has 2 menu levels, in which system-dependent settings
are made. The levels and parameters displayed depend on the modules
installed and the factory defaults. The parameters that are not required
for the selected function are not displayed.
Parameters that are not active are highlighted in grey in the display.
Operation of the control unit and the installed modules is performed via
the master control unit. The functions of the most frequently used
modules FM-MM and FM-MW are described in the instructions of the
master control unit.
The fundamental operation and calling up of the menus with the control
unit via the master control unit is described in chapter 3 from page 5.
Observe operating instructions.
To open the service menu:
Press and hold the symbol ( Fig. 2, [7], page 6) for roughly
5seconds.
The service menu overview containing the symbols for the available
functions appears.
To set parameter:
Tap corresponding symbol.
Make settings.
In the following tables the factory settings are highlighted in bold in the
"Settings/Adjustment range" column.
Table 4 Main menu
Main menu Explanation/Function Further information
General characteristic
data
Settings of the control unit, of heating system parameters and the house properties Chapter 10.1, page 13
Module configuration For selecting whether modules are detected and installed automatically or manually Chapter 10.2, page 13
Heat production Settings of the boiler data, depending on the heat source.
This can only be displayed and set if a function module FM-AM is installed.
Heating circuit data Setting of different heating circuit data (e.g. heating circuit system, maximum flow temperature)
and display of current heating curves of the relevant heating circuit
Description of the
master control unit
Domestic hot water Water treatment settings Description of the
master control unit
Reset Restore the factory settings in the main menu and in the service menu. Chapter 12, page 15
Control unit Save or load configurations. Chapter 13.2, page 16
Connectivity Activation and setting of network connection Chapter 11, page 14
Function test Check whether system components (e.g. pumps) are correctly connected.
The displays depend on which modules are installed. Depending on the operating conditions,
there may be a time delay between the demand and display.
Description of the
master control unit
Lock screen Option for blocking the screen. Description of the
master control unit
Monitor data Shows set values and actual values of the system. Tap the symbol in the footer to call up the
values.
Description of the
master control unit
Fault Displays the faults in the heating system. The remote control of the master control unit displays
the faults of the control unit to which it is linked, or is selected via the networking.
Description of the
master control unit
Chapter 13.6, page 16