Information for the user
Control 8310 – 6720856493 (2022/07)
6
3.2 Operation
The settings, operation, commissioning, fault display and
troubleshooting of the control unit and the installed module is performed
via the remote control of the master control unit.
The settings of the modules FM-MM, FM-WM are described in the
documents of the master control unit.
The settings of the module FM-AM, are described in the documents of
the module.
▶ Observe the documents of the master control unit.
If several control units are connected, the system overview with all
control units is displayed on the master control unit.
3.2.1 Display of the master control unit
System overview
The status of the overall system, the Internet connection (if available and
configured), the heat production and the system (heat distribution) can
be identified in the display of the system overview.
To select a section of the system overview:
▶Tap Heat production.
The overview of the heat generator connected to the master control
unit opens.
To view the heat distribution and the other networked control units:
▶Tap System.
Fig. 2 System overview (example)
[1] Heat production
[2] Control unit 00 (Master control unit)
[3] System (Heat distribution)
[4] Header with status display, e.g. display disabled
[5] Status display of Internet connection
(display depends on software version)
[6] Status display of the system (display depends on the
software version)
[7] Fault history, Service display
3.2.2 Networked control units
To call up the functions, displays and messages for a control unit, the
control unit in which work is carried out must always be selected first.
To select a control unit:
▶Tap on System ( Figure 2, [3], page 6).
The system overview with connected functions and control units opens.
Fig. 3 System overview (example)
[1] System of the master control unit
[2] Status display of the respective control unit
[3] Selected control unit (here, master control unit with control unit
address 00)
[4] Networked control unit (slave control unit with address 01)
[5] Changes to the view of the master control unit (only displayed
with slave control units)
[6] Connected heating circuit distributor
[7] Networked components (slave control unit with address 02)
[8] Further information on the selected control unit
[9] Press symbol to return to the previous level/screen of the selected
control unit
[10] Press symbol to access the selected control unit in the system
overview or in the control unit overview
▶ Tap on the desired control unit.
The system overview of the selected control unit opens.
Fig. 4 System overview (example)
[1] Heat production (heat generator connected to the selected
control unit)
[2] Display of selected control unit
[3] System (Heat distribution of the selected control unit)
[4] Display of the control unit address in the networking icon.
Changes to the view of the master control unit (is only displayed
with slave control units).
0010033659-001
12:00
1 32
7
5 64
0010033482-002
12:00
1 43
7 58910
2 2
02
6
0010034393-001
12:00
1 32
4
02