6 720 821 652 (2017/05) CRC200
12 | Working with the MENU
5.3 Adapting the settings for Heating with the time program (automatic mode)
Heating menu
Normally, the time program provides the best heating comfort.
If the temperatures or the time program do not meet your
needs, you can adapt the settings.
Setting the temperatures for the operating modes in the
automatic mode
A detailed description of how to change the temperatures can
be found in Chapter 4.2, Page 9.
Menu Heating > Temperatures
Adapting the start of heating and start of setback in the
Time program
Six switching times are available under each menu item in the
Time program menu (day of week or group of days). Using
these switching times, three heating phases per day can be
established. Heat begin1 represents the first switching time
for the heating mode and defines when the first heating phase
starts. Strt setback1 represents the first switching time for the
setback mode and defines when the first heating phase ends.
To set the same switching times for several days of the week,
set the switching times under Mo-Fr first. Then adapt the time
program for the individual days of the week that differ and for
Saturday and Sunday.
A detailed description of how to modify the time program can
be found in Table 10, Page 13.
Menu Heating > Time program
Menu item Description
Heating Desired room temperature for the heating
mode; if automatic mode is active, the time
program will switch to this temperature at the
start of every heating phase (42 °F ... 86 °F /
5.5 °C ... 30.0 °C). This temperature cannot be
set lower than the temperature for the setback
mode + 1 °F (+ 0.5 °C).
Setback Desired room temperature for the setback
mode; if automatic mode is active, the time
program will switch to this temperature at the
start of every setback phase (41 °F ... 85 °F /
5.0 °C ... 29.5 °C) or OFF. This temperature
cannot be set lower than the temperature for
the heating mode – 1 °F ( – 0.5 °C).
Table 8 Temperature settings in the heating menu
The switching times in the time program can be
set in 15-minute increments. In the segment
display, each segment corresponds to one
half-hour. As a result, a discrepancy of
15 minutes may occur in the segment display
of the time program. This discrepancy has no
effect on the time program.
Menu item Description
Mon-Fri It is possible to set 6 switching times for each
day (3 switching times for heat begin and
3 switching times for setback begin). The
minimum duration of a heating phase is
30 minutes.
The default settings are:
• Mon-Fri: Heat begin1: 06:00am to Strt
setback1: 11:00pm
• and Sunday: Heat begin1: 08:00am to
Strt setback1: 11:00pm
This means that you are heating from 11:00pm
in the evening until 06:00am on the following
day to the setback temperature only (Saturday
and Sunday until 08:00am).
Saturday
Sunday
Monday
Tuesday
Wednesday
Thursday
Friday
Table 9 Time program settings in the heating menu