6 720 821 652 (2017/05)CRC200
Working with the MENU | 15
Resetting the time program to the factory settings
Menu Heating > Reset Sched.
Summer switch-off (only available with weather-
compensated control)
A detailed description on how to set the summer switch-off
( ) can be found in chapter 4.1 on page 7.
Menu Heating > Summer/Winter ()
5.4 Changing the settings for water heating
Operating modes for water heating
The following statements refer to a request for hot water from
this CRC200. Water heating or temperature maintenance
remains active even if a request comes from a different
CRC200. The operating modes for hot water can be used
independently of the active operating mode for heating.
• The automatic mode for water heating is active when AUTO
appears in the value display under the menu item Mode.
There is no separate time program for water heating. The
time program for heating also specifies the switching times
for water heating. Water heating is active for a half an hour
before, during and after each heating phase (all heating
circuits). The time program for water heating is also in
effect during manual operation of the heating system.
• Continuous water heating or temperature maintenance is
active when Mode appears in the value display under the
menu item ON.
• There is no water heating or temperature maintenance
when Mode appears in the value display under the menu
item OFF.
A detailed description of how immediate tank charging is
activated and how the hot water temperature is set can be
found in Chapter 4.2, Page 9. Proceed as described in Table 6
on page 10 to change the other settings.
Menu item Description
Reset
Sched.
With the aid of the YES setting, an individual
time program can be reset to the factory
settings. All other settings are retained.
Table 11
Menu item Description
Summer/
Winter ()
If Never Heat is enabled, the heating is
turned off (for example in summer).
If Always Heat is enabled, the heating
remains active. However, the heating
appliance only starts operating if it is too cold
inside.
If by Outdoor Temp is activated, the heating
is turned on and off depending on the set
lower Temp.thresh..
Temp.thresh.
()
When the outside temperature exceeds the
temperature threshold (10,0 °C ... 30,0 °C)
set here, the heating system is switched off. If
the adjusted outside temperature falls below
the temperature threshold set here by
1 K ( °C), the heating system is switched on.
This menu item is only available when
Summer/Winter is set to by by Outdoor
Temp.
Table 12
CAUTION: Health hazard due to legionella!
▶ At lower hot water temperatures, activate
thermal Disinfection.
WARNING: Risk of scalding!
If thermal disinfection is activated to prevent
legionella, the hot water is heated once to
158 °F (70 °C) (Tuesday night at 02:00am).
The hot water temperature is set at the factory
to 140 °F (60 °C). There is a risk of scalding at
the taps if the temperature is set higher than
this.
▶ Make sure that a mixer is installed. If in
doubt, ask your contractor.