F 002 DG9 H12 | Bosch Automotive Service Solutions GmbH 2021-04-08
54 | CS LD 1.0 | Overview of parts
en |
11.1 EN 14624:2020 Test Results
The CS LD 1.0 must be checked for compliance with minimum perfor-
mance standards as per EN 14624:2020 on a calibrated leak standard at
least on an annual basis. More frequent checks may be required based on
application and region; check with your local authority to ensure compli-
ance with all local regulations.
12. Overview of parts
Item Part Number
Sensor (includes Filter tip and filter) LDB-1-CS
Parts Kit (includes sensor, filter tip, 5 filters) LDB-3-CS
Wall Charger 230V, 5V 1.0A Output LDB-4
Charger Cable, USB to Micro USB LDB-5
Carrying Case LDB-6
Filters (5 pieces) LDB-7
EN 14624:2020 Test Results Units R-134A R1234yf R-290
Static lower detection limit
1
g/a 1 1 0.5
Dynamic lower detection limit
1
g/a 1 1 0.5
Dynamic lower detection limit in a
contaminated environment
1
g/a
12 10
4
Response time
2
S 0.5 0.5 0.5
Zeroing time
2
S – – –
Recovery time
2
S 14 10 6
1
g/a - gram/annum,
2
s - Second