D6412/D4412 Operation and Installation Guide
D6412/D4412
Page 57© 2003 Bosch Security Systems 45349E
Installer’s Keypad and Installer Mode
13.3.9 Press [9] Program Key
The PK32 Programming Key functions much like a blank floppy disk and can be used to copy a system’s programming to
another system. This key can also be used as a backup in the event that the system’s programming entries are lost.
To access the PK32 Programming Key Menu, press [9] from the main programming menu. This menu contains the
following selections:
• Key to Panel: Press [1] to send information from the Programming Key to the panel.
• Panel to Key: Press [2] to send information from the panel to the Programming Key.
• Check Key: Press [3] to perform a functional diagnostic on the Programming Key. The status LED on the
Programming Key blinks during the check. When the display shows Check OK, the Programming Key is OK
for use. Press [Cmd] to abort the check.
• Erase Key: Press [4] to erase the contents of the Programming Key.
MPORTAN
A panel program stored on a PK32 key can only be used on like panel types (D6412 to D6412 and D4412 to D4412).
The PK32 connects to the pins marked AUXILIARY (JP1) on the panel’s PCB as shown in Figure 50.
R
Y
G
B
Alrm
+
PO1
AB
L-1
+
-
L-2Com L-4ComL-3 L-6ComL-5 L-8ComL-7
T
T
R
R
AUXILIARY
JP1
Installer
JP2-PO1
Select
Programming Key (PK32)
Status LED
D6412/D4412 PCB
Figure 50: PK32 to D6412/D4412 Connections