D6412/D4412 Operation and Installation Guide
D6412/D4412
Page 37© 2003 Bosch Security Systems 45349E
Off-Board Sensors Loops
8.2.6.1 DX2010 Standard Sensor Loop Wiring
The single loop configuration for DX2010 standard sensor loop wiring is shown in Figure 20.
12345678COM COM COM COM
Use 2.21 K EOL
Figure 20: DX2010 Sensor Loop Wiring, Single Loop Configuration
8.2.6.2 DX2010 Doubled Sensor Loop (Point) Wiring
The doubled loop configuration for DX2010 sensor loop wiring is shown in Figure 21.
Each loop is monitored
as a separate point.
Open for alarm
otherwise
Normally Closed
Open for alarm
otherwise
Normally Closed
2.2K
3.65K
Input
Terminals
1 to 8
Common
DX2010 Inputs
(See Tables 7 and 8)
DX2010 Inputs
(See Table 7)
Figure 21: DX2010 Sensor Loop Wiring, Doubled Loop Configuration
Tables 9 and Table 10 identify the 106 and 107 DX2010 sensor loop addresses, respectively.
DX2010 Sensor Loop
EOL 1 2 3 4 5 6 7 8
3.65 K 9 10 11 12 13 14 15 16
2.2 K 1718192021222324
Table 9: DX2010 Address 106
DX2010 Sensor Loop
EOL 1 2 3 4 5 6 7 8
3.65 K2526272829303132
2.2 K 3334353637383940
Table 10: DX2010 Address 107 (for D6412 only)
8.2.7 DX2010 Address Programming
Each DX2010 module connected to the panel must have its address jumpers set to the addresses. These address settings are
listed in Table 11.