Alarm
5 mm
(0.2 in)
4 5 6 4 5 6
1 2 3 1 2 3
|
|
- +
CVBS
MENU
µSD
E
T
H
-
P
o
E
D
A
T
A
A
L
A
R
M
Alarm
4 5 6
1 2 3
|
|
Pin
Alarm socket
1 Alarm in 1
2 Alarm in 2
3 Alarm out contact 1
4 Ground
5 Ground
6 Alarm out contact 2
The maximum wire diameter is AWG 22-28 for both stranded
and solid; cut back 5 mm (0.2 in) of insulation.
Alarm out
Use the alarm output for switching external devices such as
lamps or sirens.
Alarm output switching capability:
Max. voltage 30 VAC or +40 VDC. Max. 0.5 A continuous,
10 VA.