Page 44 from 56 6-720-821-364 SM HP270 250 - 200 2016/12 en
Code E04 Warning Code (self reset when press OK * and T top < 75ºC)
Temperature in storage tank higher than 80ºC (Detected by the hot water NTC in the top of the tank)
* Note: appliance will work if a start condition is reached, however error must be acknowledge by the user.
The Top NTC sensor is
measuring a wrong
temperature value
Unplug the NTC connection wire
and measure the NTC electrical
resistance [R] (Ω)
[R] Ω = Current Temp.
(ºC) ?
Replace wiring
Refer to table with values
in Service Manual
Yes
No
Appliance connected with
a solar thermal system?
Ensure set point in solar
control is maximum 70ºC
No
Yes
HP tank installed as back
up and receiving pre-
heated water?
Ensure máx inlet
temperature is < 70ºC
Yes
No
Appliance connected with
a boiler system?
Ensure set point in boiler
is in maximum 70ºC
Yes