EasyManua.ls Logo

Bosch HP270-2 - Troubleshooting - Code E04; E04 - Warning Code (High Tank Temperature)

Bosch HP270-2
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 44 from 56 6-720-821-364 SM HP270 250 - 200 2016/12 en
Code E04 Warning Code (self reset when press OK * and T top < 75ºC)
Temperature in storage tank higher than 80ºC (Detected by the hot water NTC in the top of the tank)
* Note: appliance will work if a start condition is reached, however error must be acknowledge by the user.
The Top NTC sensor is
measuring a wrong
temperature value
Unplug the NTC connection wire
and measure the NTC electrical
resistance [R] (Ω)
[R] Ω = Current Temp.
(ºC) ?
Replace wiring
Refer to table with values
in Service Manual
Yes
No
Appliance connected with
a solar thermal system?
Ensure set point in solar
control is maximum 70ºC
No
Yes
HP tank installed as back
up and receiving pre-
heated water?
Ensure máx inlet
temperature is < 70ºC
Yes
No
Appliance connected with
a boiler system?
Ensure set point in boiler
is in maximum 70ºC
Yes

Table of Contents

Related product manuals