Lap Trigger | 15
Bosch Motorsport DDU 9 129/148
Change signal for vehicle speed,
if desired.
Enter minimum speed for
trigger release.
Define settings for distance
based retrigger protection.
Define settings for distance
based forced trigger.
Trigger prohibited
Main Trigger
15.3.3 Distance based forced trigger
After a missed main trigger, a forced trigger is inserted, if the configured max. distance
(i.e. 120 % → 4800m) of the track distance (i.e. 4000m) has been reached. In this case, the
channel ‘Laptrigger_distlap_dls’ starts at the delta between the max. distance and the track
distance (i.e. 800m).
To deactivate distance based forced triggers, uncheck box.