Main Data Labels for Load Calculation
PALTCOR Altitude correction for relative load. If unsure, set PALTCOR
to 0.0.
MP_RL Relative load depending on throttle angle and engine
speed. Set value until your desired Lambda is matched.
Notice: For details please refer to the Function Description LOADCALC.
4.1.7 Main Data Labels for Injection
Main Data Labels for injection
CWHPI Choice LP- or HP battery voltage correction
CWINJANGMODE Choice of angle of injection relation
MP_AOINJ Map begin/end of injection
LP-system Standard choice to end of injection pulse, refers to com-
bustion TDC (degrees before TDC). Make sure, the injec-
tion is finished before the inlet valve closes. Try 200° - 300°
for first startup.
HP-system Standard choice to start of injection pulse.
Notice: Before calibration starts, turn off Lambda closed loop control.
CWLC Codeword for enabling of the Lambda closed loop control.
Set to 0 during initial calibration, afterwards = 1
4.1.8 Labels to configure Injection during Start
Conditions
After initial calibration the start factors for injection may be optimized.
Injection during start conditions
AOINJ_START_NMOT Map begin/end of injection during start
MP_INJSTART Decay of the start enrichment factor over the number of
engine revolutions
FINJSTART_TMOT Basic start enrichment factor depending on the engine
temperature
FINJSTART_NMOT Basic start enrichment factor depending on the engine
speed
Notice: For details please refer to the Function Description INJPRECTRL