5.3 USB Data Recording
The MS 6 data recording contents the feature to send a copy of the recorded data to an
USB stick. Required is just an activated USB-license and wire installation. Technical aspects
of commercial USB sticks may lead to connection- and data storage problems. Therefore
Bosch Motorsport recommends and offers just USB drive with the Bosch Order Number
F02U.V01.342‐02.
Please format the storage medium to Bosch file system available at >RaceCon / menu
bar / tools / format USB stick< before the first use. Please press >format USB stick< first,
then insert the stick.
Measure channels to verify USB data recording
usb_mediastate 0: not found
1: stick detected
2: stick installed
3: stick unplugged
4: (access)
5: error
6: corrupted
meas_cnt_forked counter of recorded data blocks