Error Memory | 9
Bosch Motorsport Engine_Control_Unit_MS_6.x_Manual 71/76
CW_EM_xxx Individual error related to a function
0 Error will not be stored in the monitor
1 Error is stored in the monitor
2 Not valid
3 Error is stored in the monitor and the MIL condition is
switched on
The single error bits may be collected in the error monitor.
9.3 Error Memory Properties
The following property is available for the error memory itself.
CLRERRMON Reset of the error monitor
Error Status /device measurement label error_state
0 No error present in the memory
1 At least one inactive error present in memory, no active er-
rors
2 At least one active error present in memory
If displayed in a measurement sheet, this property value (0, 1 or 2) is translated into a
verbal description.