EasyManua.ls Logo

Bosch Pack201HS - Page 84

Bosch Pack201HS
129 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Pack201 | Operator Interface | Section 4
EN | 53
© Bosch Packaging Technology, Inc.
All rights reserved 2012
Message Action
INCREASING FILM�
ADJUST FILM TO GET INTO REGISTRATION
DECREASING FILM
ESTOP BUTTON PRESSED� PULL OUT THE ESTOP BUTTON TO ENABLE WRAPPER START BUT-
TON
SAFETY RELAY OUTPUT CLOSE GUARD DOORS AND PULL OUT ESTOP PB’S TO ENABLE
WRAPPER START
HIGH PRODUCT STOP THE HIGH PRODUCT DETECTION CIRCUIT WAS TRIGGERED�
PRESS START TO RUN�
AUTO WAITING� MACHINE WAITING FOR SIGNAL TO RUN� CAUTION! THE MA-
CHINE MAY START AT ANY TIME!
STANDBY� WAITING FOR DOWNSTREAM
EQUIPMENT
CHECK DOWNSTREAM EQUIPMENT FOR THE REASON WHY THE
WRAPPER STOPPED� USE CAUTION! THE WRAPPER MAY START
AT ANY TIME�
LOW AIR STOP AIR PRESSURE SENSOR DETECTED LOW AIR� CHECK AIR
INPUT
MACHINE CAN NOT RUN IF NOT IN SYNC� RETURN TO MANUAL OR AUTO MODE AND PRESS START BUTTON
TO SYNC THE MACHINE�
FILM BROKEN STOP CHECK THE FILM PATH OR THE PROXIMITY SENSOR� PRESS
START TO RUN�
RESET SPLICER� PRESS THE RESET SPLICER BUTTON ON KEY PAD TO RE-ARM THE
SPLICER�
INFEED INCREASING� THE INFEED IS INCREASING TO THE NEW OFFSET
INFEED DECREASING� THE INFEED IS DECREASING TO THE NEW OFFSET
TEMPERATURE FAULT STOP LOOK AT TEMPERATURE CONTROLLER OR ITS MANUAL
FOR MORE INFORMATION�
DISCHARGE FOLLOWING ERROR� CHECK THE FEEDBACK IN E-STOP TO RESET THE FOLLOWING ER-
ROR OR PRESS START BUTTON TO RUN
LOW FILM ERROR� FILM MONITORING CIRCUIT DETECTED LOW FILM�
UNCUT REJECT NO GAP DETECTED BETWEEN PACKAGES ON THE DISCHARGE
PACKAGES INVOLVED WERE REJECTED�
SPLICE REJECT A SPLICE WAS PERFORMED AND THE PACKAGES INVOLVED
WERE REJECTED�
MANUFACTURERS SPLICE REJECT A MANUFACTURERS SPLICE WAS DETECTED AND REJECTED�
OUT OF REGISTRATION REJECT PACKAGE FOUND TO BE OUTSIDE THE PRESET LIMITS OF REGIS-
TRATION ERROR
MELTED FILM REJECT PRODUCT HELD OVER FINWHEELS LONGER THAN PRESET TIME
AND WAS REJECTED�
NO GAP / NO SEAL REJECT PRODUCT WAS DETECTED WITHIN THE PRESET WINDOW
AND REJECTED�