Pack201 | Operator Interface | Section 4
EN | 55
© Bosch Packaging Technology, Inc.
All rights reserved 2012
Message Action
OVERHEAD SWEEP INCREASING� THE SWEEP AXIS IS INCREASING TO THE NEW OFFSET
OVERHEAD SWEEP DECREASING� THE SWEEP AXIS IS DECREASING TO THE NEW OFFSET
LINESHAFT 3 INCREASING� THE LINESHAFT 3 AXIS IS INCREASING TO THE NEW OFFSET
LINESHAFT 3 DECREASING� THE LINESHAFT 3 AXIS IS DECREASING TO THE NEW OFFSET
INVALID SPEED COMP VALUE� ONE OR MORE OF THE SPEED COMPENSATED PULSES
HAS A VALUE OF COMPENSATION THAT IS GREATER THAN THE
DURATION OF A MACHINE CYCLE�
AIR CONDITIONER FAULT CHECK THE AIR CONDITIONER FOR ERRORS�
DRIVE FAULT CHECK THE DRIVE FOR ERRORS�
MOTOR OVER TEMPERATURE FAULT CHECK THE MOTOR CIRCUIT FOR ERRORS�
GENERIC WINDOW X REJECT REJECT EVENT DETECTED AND PRODUCT REJECTED�
NO GAP / NORMAL STOP PRODUCT DETECTED IN SEAL AREA WINDOW� ADJUST PRODUCT
IN TUBE AND PRESS START BUTTON TO RUN
CONSECUTIVE REJECT STOP THE PRESET AMOUNT OF CONSECUTIVE REJECTS HAS BEEN
REACHED AND THE MACHINE HAS STOPPED�
SOFT E-STOP #X� SOFT E-STOP #X HAS BEEN DETECTED�
SIDEBELT INCREASING/DECREASING� THE SIDEBELT IS INCREASING/DECREASING TO THE NEW OFFSET
HEAD AND DISCHARGE GUARD DOOR OPEN�
CLOSE THE GUARD DOOR TO ENABLE WRAPPER START
FIN AND REC GUARD DOOR OPEN�
INFEED GUARD DOOR OPEN�
FEEDER GUARD DOOR OPEN�
CODER FAULT CORRECT FAULT ON CODER AND PRESS START TO RUN THE
WRAPPER�
GENERIC WINDOW X REJECT
REJECT EVENT DETECTED AND PRODUCT REJECTED�
GENERIC INFEED WINDOW X REJECT
INVALID SPEED COMP VALUE PULSE X� ONE OR MORE OF THE SPEED COMPENSATED PULSES HAS A
VALUE OF COMPENSATION THAT IS GREATER THAN THE DURATION
OF A MACHINE CYCLE�
CONSECUTIVE HEAD JAMS� CLEAR OUT CUTTING HEAD�
PAR FILE NOT OPEN� MAKE SURE THE CORRECT FILE NAME IS ON THE COMPACT
FLASH�
WATLOW RM COMM FAULT COMMUNICATION HAS BEEN LOST TO THE WATLOW RM TEMP
CONTROLLERS�
THE USER LEVEL LOGGED IN CANNOT PER-
FORM THIS FUNCTION�
MACHINE MUST NOT BE RUNNING IN ORDER TO DO THIS� PRESS
THE STOP BUTTON IF NEEDED�