RADION receiver SD RADION receiver SD | en 21
Bosch Security Systems B.V. 2020.05 | 13 | F.01U.261.834
– ᅳP## Invisible Point = Yes (Keypads do not display alarm
activity from this point).
For UL installations, the RFBT-A shall be permanently mounted
using the 3M VHB 4956 double sided adhesive tape. The suitable
surfaces are:
– Aluminum
– Galvanized steel
– Stainless steel
– Enameled steel
– Nickel Coated ABS
– Glass (with or without Silane Coating
– PVC
– Glass/Epoxy
– PBT
– Polycarbonate
– Acrylic/Polyurethane paint
– Polyester paint
RADION universal transmitter
During the installation of the device, the following items are
required by UL:
– For UL installations, an UL Listed burglar alarm dry contact
device shall be connected if the external terminal is used.
– When external contact is configured for UL hold up
installations, a hold up device such as potter electric model
HUB is to be connected to the external contact. For
programming, refer to the appropriate control panel manual
“Special programming required for a hold up device.” Point
shall be programmed as stated below:
– P## Type = 1 Instant on open or short (Point is
constantly armed regardless of the status of the
system).
– ᅳP## Invisible Point/Silent Bell = Yes (Keypads do not
display alarm activity from this point).