RADION receiver SD RADION glassbreak | en 47
Bosch Security Systems B.V. 2020.05 | 13 | F.01U.261.834
Minimum pane
size for all types
of glass
1.2 m (4 ft)
Microphone Omni-directional 360゚ electret
Operating
Temperature
Functional range: -10°C to +49°C (+14°F to
+120°F)
UL only: 0゚C to +49゚C (+32゚F to +120゚F)
Relative
Humidity
0% to 93% (non-condensing)
Wall and
Cover Tamper
Switch
Transmits a tamper signal when someone
removes the device from its base or pulls it
away from the wall.
Frequency 433.42 MHz
Tab.5.6: Specifications
5.1 Installation considerations
For the best detector performance, select a mounting location
that is:
– Mounted on the ceiling within a maximum range of 20 ft (6
m)
– For armor-coated glass installations, mount the sensor no
more than 12 ft (3.65 m) from the glass
– Mount the detector in the direct line of sight of the glass to
be protected
– On an opposite, or adjoining wall, within a range of 20 ft (6
m) for plate, tempered, laminated, and wired glass
– In a suitable environment: temperature between -18 and
50゚C (0 and 120゚F); and humidity between 10 and 90%
non-condensing
Avoid mounting the detector in:
– Glass airlocks and glass vestibule areas
– Humid rooms