EasyManua.ls Logo

Bosch Radion B810 - Walk testing

Bosch Radion B810
96 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RADION receiver SD RADION PIR C | en 61
Bosch Security Systems B.V. 2020.05 | 13 | F.01U.261.834
Frequency 433.42 MHz
Tab.8.12: Specifications
8.1 Walk testing
Perform a walk test to determine the boundaries of the coverage
area.
Insert a slotted screwdriver into the designated hole to open the
cover and then close the detector cover to start a 90-sec Walk
Test mode.
During this test mode, motion detected within the detector’s
coverage area causes a transmitted alarm and LED activation.
Each alarm will also extend the Test Mode. Adjust as necessary.
Notice!
Excessive use of the Walk Test Mode may reduce battery life.
Use only for initial setup and maintenance testing.
Notice!
In the normal operating mode, an alarm can be transmitted only
after three (3) minutes have passed since the previous alarm
restoral. This 3 minute lockout time reduces unnecessary RF
transmissions in high traffic areas, thereby extending battery
life.
Refer to the LED table below for LED descriptions.
LED condition Cause
Steady blue PIR activation (Walk Test)
Flashing blue Warm-up period after power-up

Table of Contents

Other manuals for Bosch Radion B810

Related product manuals