Bosch Rexroth AG, RE 92650/2020-03-03
10 A1VO Series 10 | Axial piston variable pump
DRS0/DNSO – Pressure controller with load-sensing
DRS0/DNSO – Pressure controller with load-sensing
Inaddition tothe pressure controller function (DR), the
load-sensing controller works as load pressure guided flow
controller and adjusts the displacement ofthe pump tothe
quantity required by the consumer. The load-sensing
controller compares the pressure upstream the metering
orifice tothe one downstream the orifice and keeps the
pressure drop (differential pressure ∆p) occurring here and
thus the flow constant.
The swinging in by the pressure or the flow controller
always takes priority.
▶ DRS0
Setting range
1)
for pressure control 100 to250bar.
▶ DNS0
Setting range
1)
for pressure control 20 to100bar.
Notice
Version DRS0/DNSO does not have any connection
fromXtothe reservoir; thus, the LS must be unloaded in
thesystem.
▼ Characteristic curve DRS0
250
100
q
v min
q
v max
Working pressure p [bar]
Flow q
V
Hysteresis/pressure increase Δp
max
▼ Characteristic curve at variable rotational speed
q
V max
q
V min
n
min
n
max
Flow q
V
[L/min]
Rotational speed n
Hysteresis Δq
V
max
▼ Circuit diagram DRS0
S0
DR
L
2
L
1
B
1
S
X
1 The metering orifice (control block) is not included in the
scopeofdelivery.
Differential pressure ∆p
Standard setting: 14 bar. If another setting is required,
please state in the plain text.
Controller data
For data for the pressure controller DR, please refer
topage9. Maximum flow differential (hysteresis
andincrease) measured at drive speed n = 1500 rpm
andt
fluid
=50 °C
NG 18 28 35
Volume flow difference Δq
V max
3 l/min
Maximum pilot fluid consumption approx. 4 l/min
1) Inorder toprevent damage tothe pump and the system,
thepermissible setting range must not beexceeded.
Lower values on request