RE 92650/2020-03-03, Bosch Rexroth AG
9 Axial piston variable pump | A1VO Series 10
DR/DN – Pressure controller
DR/DN – Pressure controller
The pressure controller limits the maximum pressure at the
pump outlet within the control range ofthe variable pump.
The variable pump only supplies as much hydraulic fluid as
isrequired bythe consumers. If the working pressure
exceeds the pressure command value at the pressure valve,
the pump will regulate toasmaller displacement toreduce
the control differential.
▶ Basic position indepressurized state:V
g max
.
▶ DR
Setting range
1)
for pressure control 100 to250bar.
Standard is250bar
DN
Setting range
1)
for pressure control 20 to100bar.
Standard is100bar
▼ Characteristic curve DR
250
q
v min
q
v max
100
Working pressure p [bar]
Flow q
V
Hysteresis/pressure increase Δp
max
▼ Circuit diagram DR
L
L
S
Controller data
NG 18 28 35
Hysteresis and repeat precision Δp
Maximum 5 bar
Pilot fluid consumption Approx. 3 l/min maximum
1) Inorder toprevent damage tothe pump and the system,
thepermissible setting range must not beexceeded.
Lower values on request