Bosch Rexroth AG, RE 92650/2020-03-03
4 A1VO Series 10 | Axial piston variable pump
Hydraulic fluid
Hydraulic fluid
The axial piston unit A1VO isdesigned for operation
withHLP mineral oil according toDIN 51524.
Application instructions and requirements for
hydraulicfluid selection, behavior during operation
aswellasdisposal and environmental protection should
betaken from the following data sheets before the start
ofproject planning:
▶ 90220: Hydraulic fluids based onmineral oils and
related hydrocarbons
Selection ofhydraulic fluid
BoschRexroth evaluates hydraulic fluids onthebasis
oftheFluid Rating according tothe technical
datasheet90235.
Hydraulic fluids with positive evaluation inthe Fluid Rating
are provided inthe following technical datasheet:
▶ 90245: BoschRexroth Fluid Rating List forRexroth
hydraulic components (pumps and motors)
Selection ofhydraulic fluid shall make surethat
theoperating viscosity inthe operating temperature range
iswithin theoptimum range (ν
opt
; see selection diagram).
Viscosity and temperature ofhydraulic fluids
Viscosity Shaft seal Temperature
2)
Comment
Cold start
ν
max
≤ 1600 mm²/s
FKM ϑ
St
≥-25 °C
t ≤ 3 min, without load (p ≤ 50 bar), n ≤ 1000 rpm
Permissible temperature difference between axial piston
unitand hydraulic fluid inthe system maximum 25 K
Warm-up phase
ν = 1600 … 400 mm²/s t ≤ 15 min, p ≤ 0.7×p
nom
and n ≤ 0.5×n
nom
Continuous
operation
ν = 400 … 10 mm²/s
1)
FKM ϑ ≤ +90 °C measured at port L
ν
opt
= 36 … 16 mm²/s
optimal operating viscosity and efficiency range
Short-term
operation
ν
min
= 10 … 7 mm²/s
FKM ϑ ≤ +90 °C
t ≤ 1 min, p ≤ 0.3×p
nom
, measured at port L
▼ Selection diagram
−25 −10 10 30 40 50 90 11570
0
7
10
40
60
20
100
200
400
600
1000
1600
VG 22
VG 32
VG 46
VG 68
VG 100
16
36
Viscosity ν [mm
2
/s]
Maximum permissible viscosity oncold start
Warm-up phase
Continuous operation
ν
opt
Minimum permissible viscosity forshort-term operation
Temperature
ϑ [°C]
1) This corresponds, forexample ontheVG46, toatemperature
range of+4 °C to+85 °C (see selection diagram)
2) If thetemperature atextreme operating parameters cannot
beadhered to, please contact us.