BoschRexrothAG, RE 91485-01-B/2021-11-18
28/72 A10FZO, A10VZO, A10FZG and A10VZG series 10 | Transport and storage
Abb� 10: Mounting the eye bolt
WARNING! Danger due to suspended loads!
During transport with lifting strap, the axial piston unit can topple out of the lifting
strap and cause injury.
▶ Use the widest possible lifting strap.
▶ Make sure that the axial piston unit is securely fixed with the lifting strap.
▶ Only guide the axial piston unit by hand for fine positioning and to avoid
swinging.
▶ Never step or grip under suspended loads.
▶ Place the lifting strap around the axial piston unit in such away that it does not
pass over assembled parts (e.g.valves, piping) and that the axial piston unit is
not suspended from assembled parts (see Abb. 11).
Abb� 11: Transport with lifting strap; example A10VZO
6�2 Storing the axial piston unit
• Storage areas should be free of corrosive materials and gases.
• To prevent damage to the seals, do not operate ozone-forming equipment
(e.g.mercury-vapor lamps, high-voltage equipment, electric motors, sources of
electrical sparks or electrical discharge) in storage areas.
Transport with lifting strap
Requirement