38/72 A10FZO, A10VZO, A10FZG and A10VZG series 10 | Installation
6 7 8
L
L
1
F
SB
h
s max
h
t min
h
min
h
ES min
S
SB
F
L
L
1
h
s max
h
t min
h
min
h
ES min
S
SB
F
L
L
1
h
s max
h
t min
h
min
h
ES min
S
Abb� 18: Above-reservoir installation A10VZO with installation position 6–8
Tabelle 20: Above-reservoir installation
Installation position Air bleed Filling
6 (drive shaft horizontal) F L
7 (drive shaft vertically up) F L
1
8 (drive shaft vertically down) F L
L,
L
1
Drain port
F Filling/air bleeding
S (A/B) Suction port
h
t min
Minimum required immersion depth
(200 mm)
h
min
Minimum required distance to
reservoir bottom (100mm)
h
ES min
Minimum height required to prevent
axial piston unit from draining
(25mm)
h
S max
Maximum permissible suction height
(800mm)
SB Baffle (baffle plate)
7�4 Installation position A10FZG, A10VZG
The following installation positions are permissible. The pipeline routing shown
illustrates the basic layout.
7�4�1 Below-reservoir installation (standard)
Below-reservoir installation means that the axial piston unit is installed outside of
the reservoir below the minimum fluid level.
Recommended installation position: 1.
Because complete air bleeding and filling is not possible in installation
positions 2 and 3, the axial piston unit must be air bled and filled in
ahorizontal position prior to installation.