BoschRexrothAG, RE 91485-01-B/2021-11-18
36/72 A10FZO, A10VZO, A10FZG and A10VZG series 10 | Installation
Tabelle 17: Inside-reservoir installation
Installation position Air bleed Filling
4 (drive shaft horizontal) Via the highest
available port L
Automatically via the open
port L, by position below
hydraulic fluid level
5 (drive shaft vertically up) Via the highest
available port
L (NG3 to 18)
L
1
(NG21 to 63)
Automatically via the open
port L or L
1
due to the
position under the hydraulic
fluid level
4 5
L
L
1
SB
h
min
h
t min
S
L
L
1
h
min
SB
h
t min
S
Abb� 16: Inside-reservoir installation A10VZO with installation position 4–5
Tabelle 18: Inside-reservoir installation
Installation position Air bleed Filling
4 (drive shaft horizontal) Via the highest
available port L
Automatically via the open
port L or L
1
due to the
position under the hydraulic
fluid level
5 (drive shaft vertically up) Via the highest
available port L
1
Automatically via the open
port L or L
1
due to the
position under the hydraulic
fluid level
L,
L
1
Drain port
F Filling/air bleeding
S (A/B) Suction port
h
t min
Minimum required immersion depth
(200 mm)
h
min
Minimum required distance to
reservoir bottom (100mm)
SB Baffle (baffle plate)
7�3�3 Above-reservoir installation
Above-reservoir installation means that the axial piston unit is installed above the
minimum fluid level of the reservoir.
Observe the maximum permissible suction height h
S max
= 800 mm.
The permissible suction height h
S
is derived from the total pressure loss.